The C.Scope SGV4 is a One Watt dual-frequency (33+131kHz) Signal Generator with in-built Data Logging. Designed for use with a CXL4 or DXL4 Cable Avoidance Tool. Network Rail Approved.
The C.Scope SGV4 Signal Generator is designed for use alongside a CXL4 or DXL4 Cable Avoidance Tool. It enables significantly more underground utilities to be detected including street lighting cables.
SIMULTANEOUS DUAL-FREQUENCY The simultaneous dual-frequency 33kHz and 131kHz signal output of the Signal Generators is ideal for maximising the number of buried services that can be energised and then detected.
The SGV4 Signal Generator can apply the dual frequency signal without direct connection to buried services, using either a Signal Clamp or the simple induction method from ground level, providing a significant improvement in the detection of the smaller diameter or poorly earthed cables.
THREE SIGNAL APPLICATION TECHNIQUES The SGV4 offers three alternative ways to apply a Signal Generator signal:
Direct Connection allows specific pipes or cables to be individually traced, identified and their depths measured. The use of Signal Clamps, Signal Injectors and Direct Connection leads make this mode the most effective method for pinpointing pipes and cables.
If it is difficult or inconvenient to use Direct Connection, then the Wraparound technique can be utilised to successfully energise a street or car park lighting cable.
Induction allows the Signal Generator to induce a detectable and traceable signal to previously unknown, undetected or inaccessible underground metal pipes or cables.
HIGH POWER SIGNAL The fully adjustable One Watt Power Output of the SGV4 means that deeper and less conducting pipes and cables can be effectively energised and then traced over ever longer distances.
It also features a FOUR position power level adjustment so the operator has total control of how much power is in use and when.
PULSED/CONTINUOUS SIGNAL OUTPUT A Pulsed or Continuous signal output allows operators to switch to the Pulsed Mode at the push of a button in high interference situations and keep on tracing. The SGV4 has a clear audible signal output to indicate when it is in operation.
A useful in-built audio mute control is also included.
DATA LOGGING To compliment and support in-built data logging on the Cable Avoidance Tools, the SGV4 Signal Generator also has full data logging capability. A years worth of data can be stored, in normal usage, on both the Locator and Signal Generator. This can be conveniently transferred at any time via a USB to a supervisors PC for analysis.
CALIBRATION The SGV4 Signal Generators do not require periodic recalibration. A fully Automatic Daily Self Test (ADST) tests and confirms that they are functioning at their optimum level each day.
AUTOMATIC DAILY SELF TEST (ADST) The SGV4 Signal Generators perform a comprehensive Automatic Daily Self Test (ADST).
At the start of each day of use, a positive Automatic Daily Self Test result gives confirmation to the operator that the kit is working at the optimum level.
The result of this test is recorded and stored on memory within the products in-built data files and can be downloaded onto a PC at any time within the following 12 months*.
PRODUCT VALIDATION CERTIFICATION These test results can be used to produce a Product Validation Certificate using the C.Scope PC Toolkit. In addition, any results of the Self Test that have been carried out in the last twelve months* are available. The PC Toolkit can also be used to view and print a copy of the original factory Calibration Certificate.
C.Scope authorised Service Centres are also able to provide third-party Test and Calibration Certification should you require it to comply with client or internal requirements.
HIGH RESOLUTION BACKLIT DIGITAL DISPLAY The SGV4 has a large, clear and easy to read backlit LCD mounted behind a protective polycarbonate lens. The display indicates functions selected, power level, connection quality and battery condition. It also displays the Automatic Daily Self Test results.
ROBUST AND DURABLE CONSTRUCTION The SGV4s twin wall construction is robust and durable. It also provides IP65 standard protection against dust and water ingress.
ACCESSORY TRAY The SGV4 Signal Generator has a large detachable accessory tray as its base. It can house not only the standard accessories (Direct Connection Leads, Earth Stake, Connection Magnets, 10m Auxiliary Earth Lead) and the Instruction Manual but also many of the optional extras such as Signal Clamps, Sondes and Signal Injectors.
THREE YEAR WARRANTY The SGV4 comes with a three year Warranty (conditions apply).
Overview
Specification
Product name SGV4 Signal Generator
Part No. SGV4
Controls All operation is by push button control as follows:
Audio Indications
Visual Indication Multi-segment Liquid Crystal Display indicating:
Data Connector Standard USB Mini B connector. USB 2.0 Compatible
Self Test Automatic Daily Self Test and manual Self Test function
Output
Connected Mode
Construction
Weight (including batteries, Connection Leads and Earth Stake 3.4kg (7 lb 7 oz)
Dimensions (with Accessory Tray fitted) 360mm x 180mm x 230mm (14.1” x 7” x 9”)
Battery Type Internal 4 x ‘D’ (LR20) cells (either alkaline non-rechargeable or NiMH rechargeable)
Battery Life up to 40 hours intermittent use at 20ºC (68ºF) using alkaline cells
IP Rating 65
Network Rail Approved
Notes Performance figures stated can be affected by site parameters such as ground conditions, temperature, and strong electromagnetic fields. Specification may be subject to change. All C.Scope Signal Generators are in compliance with the essential requirements and other relevant provisions of Council Directive 2014/53/EU (EMC). Compliance has been demonstrated by testing representative samples to the harmonised standards EN300-330 and EN301-489. The essential radio test suites have been carried out and the equipment is in conformity with all applicable directives. All C.Scope Signal Generators comply with the essential requirements and other provisions of Council Directive 2011/65/EU (RoHS).
* No Periodic Calibration. The SGV4 does not require periodic recalibration. A Product Validation Certificate can be printed using the PC Toolkit. C.Scope authorised Service Centres are also able to provide third-party Test and Calibration Certification should you require it to comply with client or internal regulations.
** Three Year warranty. Conditions apply.
*** Batteries. 4 x D LR20 Alkaline or NiMH Rechargeable batteries housed in a secure battery compartment.
**** In-Built Accessory Tray includes Direct Connection Lead, Auxiliary 10m Earth Lead, Connection Magnets, Earth Stake and Instruction Manual